Aluminum

*Product images are for illustrative purposes only and may differ from the actual product.

Quadruplex Service Drop - 600V - Aluminum

600V Quadruplex
Aluminum Conductor
PE or XLPE Insulation

x

Please select all above options before adding to cart.
Construction
Category Conductor Description Concentrically stranded, compressed 1350-H19 aluminum
Category Insulation Description Polyethylene (PE) or Cross-Linked Polyethylene (XLPE)
Category Assembly Description Three insulated aluminum conductors with a bare neutral-messenger
  • Used to supply power, usually from a pole mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at 600 volts or less phase to phase. Not to exceed 75°C for PE and 90°C for XLP
  • ASTM - B-230 Aluminum Wire,1350-H19 for electrical purposes
  • ASTM - B-231 Aluminum Conductors, Concentric-Lay-Stranded
  • ASTM - B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced
  • ICEA S-61-402 and ICEA S66-524

Questions & Answers

Ask a Question

Part Number Table

Part # Phase Conductor AWG Phase Conductor Stranding Phase Conductor Insul. Thick. Mils Neutral AWG Bare Neutral Rated Strength Lbs. Lbs./M (XLP) Lbs./M (PE)
Morochuca 6 Solid 45 6 1190 152 147.4
CHOLA 6 7 45 6 1190 162 153
French Coach 6 7 45 6 1110 155 144.3
Bay 6 Solid 45 6 1110 145 140
HACKNEY 4 7 45 4 1860 241 229
Pinto 4 7 45 4 881 223 207.9
Clydesdale 4 Solid 45 4 881 208 201.8
German Coach 4 Solid 45 4 1760 214 208.3
Morgan 4 Solid 45 4 1860 226 220
Arabian 4 7 45 4 1760 229 214.4
BELGIAN 2 7 45 2 2800 344 323.1
Mustang 2 7 45 2 1350 333 312.6
PALOMINO 2 7 45 2 2850 362 347
COSTENA 1/0 19 60 1/0 4380 547.2 478
Shetland 1/0 19 60 1/0 4460 546 521.1
Criollo 1/0 19 60 1/0 1990 529 504.5
Percheron 2/0 19 60 2/0 2510 649 620.5
GRULLO 2/0 19 60 2/0 5310 707 677
Thoroughbred 2/0 19 60 2/0 5390 670 641.5
Trotter 3/0 19 60 3/0 6790 825 791.8
SUFFOLK 3/0 19 60 3/0 6620 872 838.9
Hanoverian 3/0 19 60 3/0 3310 799 765.6
Walking 4/0 19 60 4/0 8560 1019 979.7
Oldenburg 4/0 19 60 4/0 4020 986 946.7
APPALOOSA 4/0 19 60 4/0 8350 1038 1038
Geiding 336.4 19 80 4/0 8350 1548 1494.3
Lippizaner 336.4 19 80 336.4 6146 1546 1519.2
BRONCO 336.4 19 80 336.4 8580 1553.8 1568.2

*Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201 *Conductor temperature of 90°C for XLP, 75°C for Poly-ambient temperatures of 40°C Note: The data shown is approximate and subject to standard industry and manufacturer tolerances