Zoom In
Zoom Out
Enlarge
*Product images are for illustrative purposes only and may differ from the actual product.
CCW Instrumentation; Ind. & Overall Shield; PVC Jacket; 90°C
Continuously Corrugated Welded Cable – CCW®
PVC/Nylon - PVC Jackets
Pairs & Triads – Individual & Overall Shields
90°C – 600 Volt
Construction |
Category Conductor Description |
Bare, annealed copper conforming to ASTM B3 and stranded in accordance with ASTM B8 (Class B)
|
Category Insulation Description |
Flame-retardant Polyvinyl Chloride (PVC) insulation and nylon covering, rated 90°C per UL Standard 83
Color Code: ICEA Method 1
|
Individual Shield |
Isolated and individually twisted pairs or triads with an aluminum/polyester tape shield providing 100% coverage
Drain wire
|
Overall Shield |
Aluminum/polyester tape shield providing 100% coverage
Drain wire
|
Inner Jacket |
Flame retardant Polyvinyl Chloride (PVC) per UL 1569, black
Low temp performance meets ASTM D746 brttleness temp at or below -40°C
Nylon ripcord
|
Armor |
Impervious, continuously corrugated and welded aluminum per UL 1569 & 2225
Meets grounding requirements of NEC Article 250
|
Overall Jacket |
Flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) per UL Standards 1569, black
Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
|
-
For use as instrumentation tray cable on circuits rated 150V or less and 5 amps or less in accordance with NEC article 727
-
Recognized for use in Class I, II, and III, Divisions 1 and 2; or Class 1, Zones 1 and 2 hazardous locations per NEC articles 501, 502, 503 and 505
-
Installed indoors and outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
-
Recognized for use on fixed or floating offshore petroleum facilities as recommended by American Petroleum Institute
-
UL Type MC-HL
-
UL 83, 1569, 2225, 1309 and 1581
-
IEEE 1202 available upon request
Part Number Table
Part # |
Gauge |
Pairs |
Triads |
Nominal OD over Core |
Nominal OD over Armor |
Nominal OD Overall |
Material Weight (Lbs./M') |
XL41812 |
18 |
12 |
- |
.780 |
1.00 |
1.105 |
560 |
XL41824 |
18 |
24 |
- |
1.08 |
1.39 |
1.49 |
969 |
XL41602 |
16 |
2 |
- |
.450 |
.670 |
.780 |
246 |
XL41604 |
16 |
4 |
- |
.560 |
.800 |
.910 |
346 |
XL41608 |
16 |
8 |
- |
.700 |
.930 |
1.04 |
502 |
XL41612 |
16 |
12 |
- |
.850 |
1.11 |
1.22 |
670 |
XL41624 |
16 |
24 |
- |
1.12 |
1.42 |
1.53 |
1336 |
XL41636 |
16 |
36 |
- |
1.37 |
1.69 |
1.82 |
2184 |
XL51604 |
16 |
- |
4 |
.610 |
.840 |
.950 |
428 |
XL51608 |
16 |
- |
8 |
.820 |
1.06 |
1.17 |
694 |
XL51612 |
16 |
- |
12 |
.980 |
1.24 |
1.35 |
958 |
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances
General Cable CCW® is a registered trademark of General Cable