HW171- TRAY CABLE - LifeGuard™ SHIELDED CONTROL CABLE 600 Volt UL Type TC-LS, 90°C

*Product images are for illustrative purposes only and may differ from the actual product.

HW171- TRAY CABLE - LifeGuard™ SHIELDED CONTROL CABLE 600 Volt UL Type TC-LS, 90°C


Please select all above options before adding to cart.
Construction
Category Conductor Description Tin coated soft annealed copper per ASTM B-33, Class B stranding per ASTM B-8
Category Jacket Description Sunlight-resistant and flame-retardant, Low Smoke Zero Halogen polyolefin per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping
Category Insulation Description Tin coated soft annealed copper per ASTM B-33, Class B stranding per ASTM B-8
Overall Shield Aluminum-polymer tape providing 100% coverage with a flexible 7 strand tinned copper drain wire
Category Applications LifeGuard™ jacket is highly flame-retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™ cable is ideal for applications where a high degree of safety and equipment protection is required. LifeGuard™ cable is UL listed as Type TC-LS and approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts. It may be installed in temperatures as low as -30°C and used in NEC Class I and II, Division 2 hazardous locations. It is UL approved for continuous operation at 90°C in wet and dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Exposed Run (ER) rating available upon request.
  • LifeGuard™ jacket is highly flame-retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™ cable is ideal for applications where a high degree of safety and equipment protection is required. LifeGuard™ cable is UL listed as Type TC-LS and approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts. It may be installed in temperatures as low as -30°C and used in NEC Class I and II, Division 2 hazardous locations. It is UL approved for continuous operation at 90°C in wet and dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Exposed Run (ER) rating available upon request.

Questions & Answers

Ask a Question

Part Number Table

Part # Gauge Conductors Stranding Insulation Thickness Outside Diameter Inches Material Weight (Lbs./M')
HW17101803 18 3 7 30 0.33 53
HW17101602 16 2 7 30 0.33 59
HW17101603 16 3 7 30 0.35 67
HW17101604 16 4 7 30 0.38 92
HW17101605 16 5 7 30 0.42 109
HW17101607 16 7 7 30 0.45 135
HW17101609 16 9 7 30 0.56 188
HW17101612 16 13 7 30 0.62 232
HW17101615 16 15 7 30 0.69 281
HW17101619 16 19 7 30 0.72 322