HW172: LifeGuard™ 600V Power Cable, XLP XHHW-2, LSZH

*Product images are for illustrative purposes only and may differ from the actual product.

HW172: LifeGuard™ 600V Power Cable, XLP XHHW-2, LSZH


Please select all above options before adding to cart.
Construction
Category Conductor Description Tin coated soft annealed copper per ASTM B-33, Class B stranding per ASTM B-8
Category Jacket Description Sunlight-resistant and flame-retardant, Low Smoke Zero Halogen polyolefin per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping
Category Insulation Description Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2 conductors
Category Standards NEC Type TC per articles 336, 392, and 501.4 (b) and Class 1 circuits per NEC article 725
Category Applications LifeGuard™ jacket is highly flame retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™ cable is ideal for applications where a high degree of safety and equipment protection is required. LifeGuard™ cable is UL listed as Type TC-LS and approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts. It may be installed in temperatures as low as -30°C and used in NEC Class I and II, Division 2 hazardous locations. It is UL approved for continuous operation at 90°C in wet and dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Exposed Run (ER) rating available upon request.
  • LifeGuard™ jacket is highly flame retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™ cable is ideal for applications where a high degree of safety and equipment protection is required. LifeGuard™ cable is UL listed as Type TC-LS and approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts. It may be installed in temperatures as low as -30°C and used in NEC Class I and II, Division 2 hazardous locations. It is UL approved for continuous operation at 90°C in wet and dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Exposed Run (ER) rating available upon request.
  • NEC Type TC per articles 336, 392, and 501.4 (b) and Class 1 circuits per NEC article 725

Questions & Answers

Ask a Question

Part Number Table

Part # Gauge Conductors Stranding Insulation Thickness Outside Diameter Inches Weight Material Weight (Lbs./M')
HW17200803 8 3 7 45 0.63 238.000 238
HW1720803G 8 3 7 45 0.63 267.000 267
HW17200804 8 4 7 45 0.7 305.000 305
HW1720804G 8 4 7 45 0.7 339.000 339
HW17200603 6 3 7 45 0.71 390.000 390
HW1720603G 6 3 7 45 0.71 437.000 437
HW17200604 6 4 7 45 0.78 497.000 497
HW1720604G 6 4 7 45 0.78 495.000 495
HW17200403 4 3 7 45 0.81 564.000 564
HW1720403G 4 3 7 45 0.81 612.000 612
HW17200404 4 4 7 45 0.94 763.000 763
HW1720404G 4 4 7 45 0.94 814.000 814
HW1720203G 2 3 7 45 0.98 867.000 867
HW1720204G 2 4 7 45 1.08 1087.000 1087
HW1721003G 1/0 3 19 55 1.2 1390.000 1390
HW1721004G 1/0 4 19 55 1.3 1676.000 1676
HW1722004G 2/0 4 19 55 1.34 1934.000 1934
HW1722003G 2/0 3 19 55 1.44 2780.000 2780
HW1724003G 4/0 3 19 55 1.53 2523.000 2523
HW1724004G 4/0 4 19 55 1.79 3630.000 3630
HW1722503G 250 3 37 65 1.78 3296.000 3296
HW1722504G 250 4 37 65 1.9 4210.000 4210
HW1723503G 350 3 37 65 2 3643.000 3643
HW1723504G 350 4 37 65 2.21 4743.000 4743
HW1725003G 500 3 37 65 2.29 6116.000 6116
HW1725004G 500 4 37 65 2.54 7881.000 7881
HW1727503G 750 3 61 80 2.81 9101.000 9101