Medium Voltage

Choose Favorites List
Zoom In Zoom Out Enlarge

*Product images are for illustrative purposes only and may differ from the actual product.

    15kV - EPR Insulation, CPE Jacket

    EPR Insulation - CPE Jacket
    15 kV, EPR/Copper Tape Shield
    UL Type MV-105
    133% Insulation Levels

    x

    Please select all above options before adding to cart.
    Construction
    Category Conductor Description 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand
    Extruded Strand Shield Extruded thermoset semi-conducting stress-control layer over conductor
    Category Insulation Description Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers
    Extruded Insulation Shield Thermoset semi-conducting polymeric layer free stripping from insulation
    Metallic Shield 5 mil annealed copper tape with an overlap of 25%
    Category Jacket Description Flame-retardant, moisture- and sunlight-resistant Chlorinated Polyethylene (CPE)
    • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications
    • For use in wet or dry locations when installed in accordance with NEC
    • For use in aerial, conduit, open tray and underground duct installations
    • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5)
    • National Electrical Code (NEC)
    • UL 1072
    • ICEA S-93-639/NEMA WC74
    • ICEA S-97-682
    • AEIC CS8
    • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
    • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test
    • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC
    • IEEE 1202 (70,000 BTU/hr)/CSA FT4
    • EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA Acceptable

    Questions & Answers

    Ask a Question

    Part Number Table

    Part # Gauge Conductor Diameter Insulation Diameter Min Insulation Diameter Max Jacket Thickness Outside Diameter Inches Material Weight (Lbs./M')
    MVEH30201 2 .270" .710" .800" 0.08 0.99 655
    MVEH30101 1 .310" .745" .830" 0.08 1.02 730
    MVEH31/001 1/0 .340" .780" .865" 0.08 1.06 820
    MVEH32/001 2/0 .380" .820" .905" 0.08 1.1 933
    MVEH33/001 3/0 .430" .865" .955" 0.08 1.14 1072
    MVEH34/001 4/0 .480" .920" 1.005" 0.08 1.21 1248
    MVEH325001 250 .530" .970" 1.060" 0.08 1.25 1402
    MVEH335001 350 .620" 1.070" 1.155" 0.08 1.35 1778
    MVEH350001 500 .740" 1.190" 1.275" 0.08 1.47 2325
    MVEH375001 750 .910" 1.370" 1.460" 0.08 1.65 3250

    Note: The data shown are approximate and subject to standard industry and manufacturer tolerances