Non-Metallic Sheathed with Signal Pair

*Product images are for illustrative purposes only and may differ from the actual product.

Non-Metallic Sheathed with Signal Pair

Nonmetallic-Sheathed Cable with both Power Conductors and Control/Signal Conductors. 600 Volts. Copper Conductors. Color-Coded Jacket.

Please select all above options before adding to cart.
Construction
Category Description NM-B PCS cable is manufactured as 2 or 3 insulated copper power conductors with a bare ground wire plus a control/signal component for installation as a Class 2 or Class 3 circuit, all underneath an outer PVC jacket that includes a blue stripe over the control/signal component. Control/signal component is a pair of solid copper 16 AWG purple and pink conductors underneath a 30 mil light blue PVC jacket. Copper conductors are annealed (soft) copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. NM-B-PCS cable is designed for easier pulling, resulting in easier installation. The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow - 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG.
Applications NM-B-PCS (nonmetallic-sheathed with signal pairs) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code. NM-B-PCS cable is primarily used in residential wiring for SMART home applications such as 0-10V DC dimming controls for LED lighting. NM-B-PCS cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B-PCS cable is 600 volts. All conductors are rated 600 volts.
Category Standards Compliant with NEC Article 334 (NM Cable) and the Class 2/Class 3 circuit separation requirements of NEC 725.136(I)(1) and 725.136(I)(2) Listed per UL Standard 719 ASTM B-3 and B-8 Federal Specification A-A-59544 REACH/RoHS Compliant
  • Compliant with NEC Article 334 (NM Cable) and the Class 2/Class 3 circuit separation requirements of NEC 725.136(I)(1) and 725.136(I)(2)
  • Listed per UL Standard 719
  • ASTM B-3 and B-8
  • Federal Specification A-A-59544
  • REACH/RoHS Compliant

Questions & Answers

Ask a Question

Part Number Table

Part # Conductors Gauge Insulation Thickness Stranding Jacket Thickness Material Weight (Lbs./M')
NM-B PCS 12/2 2 12 15 1 5 135
NM-B-PCS 14/2 2 14 15 1 5 110