Instrumentation Cable

*Product images are for illustrative purposes only and may differ from the actual product.

FREP® - Multiple Triads - Individual & Overall Shield

FREP® - Multiple Triads
CPE Jacket - FR-EP Insulation
Individual & Overall Shield

x

Please select all above options before adding to cart.
Construction
Category Conductor Description 7 strand soft drawn tinned copper, class B per ASTM B8 and B33
Category Insulation Description Flame-retardant Ethylene Propylene Rubber (EPR)
Individual Shield Aluminum/Mylar shielding tape
Drain Wire Tinned copper applied helically over core and twisted triads
Overall Shield Aluminum/Mylar shielding tape
Category Jacket Description Chlorinated Polyethylene (CPE)
Ripcord Nylon
  • Process instrumentation applications where resistance to moisture, chemicals, thermal stability, and physical durability are essential.
  • Used in high performance applications where reliability is essential
  • Rated 90°C Wet or Dry
  • UL Type TC
  • ICEA S-82-552 - 600 Volt
  • IEEE 1202 available upon request
  • ICEA T-29-520-(210,000 BTU/hr)
  • UL Subject 1277 (70,000 BTU/hr)
  • OSHA Acceptable

Questions & Answers

Ask a Question

Part Number Table

Part # Gauge Triads Insulation Thickness Jacket Thickness Outside Diameter Inches Material Weight (Lbs./M')
AF71802 18 2 0.025 0.06 0.56 127
AF71804 18 4 0.025 0.06 0.655 201
AF71808 18 8 0.025 0.08 0.885 365
AF71812 18 12 0.025 0.08 1.07 547
AF71816 18 16 0.025 0.08 1.18 693
AF71820 18 20 0.025 0.08 1.31 841
AF71824 18 24 0.025 0.08 1.42 985
AF71836 18 36 0.025 0.08 1.67 1407
AF71601 16 1 0.025 0.045 0.335 66
AF71602 16 2 0.025 0.06 0.615 159
AF71604 16 4 0.025 0.06 0.705 249
AF71606 16 6 0.025 0.06 1.378 348
AF71608 16 8 0.025 0.08 0.85 472
AF71612 16 12 0.025 0.08 1.16 683
AF71616 16 16 0.025 0.08 1.31 922
AF71620 16 20 0.025 0.08 1.46 1121
AF71624 16 24 0.025 0.08 1.58 1323
AF71636 16 36 0.025 0.11 1.92 2012

Note: The data shown are approximate and subject to standard industry and manufacturer tolerances.