15kV - CCW Armored Power, 133%, Shielded, 3/C
Part #: XMVE335003
Continuously Corrugated Welded Cable – CCW®
133% EPR Insulation – PVC Jacket
105°C – UL Type MC-HL or MV-105
15kV – 3-Conductor – Shielded
Construction |
Category Conductor Description |
Bare annealed copper per ASTM B3
Compact stranding per ASTM B496
|
Extruded Strand Shield |
Extruded thermoset semi-conductor stress control layer over conductor per ICEA S-93-639 and UL 1072
|
Category Insulation Description |
Ethylene Propylene Rubber (EPR)
|
Extruded Insulation Shield |
Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072
|
Grounding Conductor |
Class B stranded bare annealed copper grounding conductor
Sized in accordance with UL 1072 and NEC Article 250
|
Shield |
5 mil annealed bare copper tape with 25% overlap
Color coded polymeric identification tape laid under the shield: Black, Red, & Blue
|
Armor |
Impervious, continuously welded and corrugated aluminum alloy sheath
|
Category Jacket Description |
Flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC), red
Low temperature performance meets ASTM D746 brittleness temperature at or below 40°C
|
-
For use in feeders and branch circuits in industrial power distribution systems per NEC articles 328 and 330
-
Approved for Classes I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2, hazardous locations covered under NEC Articles 501, 502, 503 and 505
-
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced no more than 6 feet apart Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete
-
UL 1072
-
UL 1569
-
UL 2225
-
UL 1309
-
IEEE 1202 available upon request
Part Number Table
Part # |
Gauge |
Conductors |
Ground Gauge |
Insulation Thickness |
Nominal OD over Armor |
Nominal OD Overall |
Material Weight (Lbs./M') |
XMVE30203 |
2 |
3 |
6 |
0.22 |
2.15 |
2.28 |
2507 |
XMVE31/003 |
1/0 |
3 |
4 |
0.22 |
2.32 |
2.48 |
3190 |
XMVE32/003 |
2/0 |
3 |
4 |
0.22 |
2.40 |
2.56 |
3582 |
XMVE34/003 |
4/0 |
3 |
3 |
0.22 |
2.62 |
2.79 |
4549 |
XMVE325003 |
250 |
3 |
3 |
0.22 |
2.75 |
2.92 |
5086 |
XMVE335003 |
350 |
3 |
2 |
0.22 |
3.03 |
3.21 |
6594 |
XMVE350003 |
500 |
3 |
1 |
0.22 |
3.32 |
3.50 |
8570 |
XMVE375003 |
750 |
3 |
1/0 |
0.22 |
3.80 |
3.98 |
11549 |
Note: The data shown are approximate and subject to standard industry and manufacturer tolerances. Please verify specific requirements with your Omni Cable account manager