OmniCable offers a wide selection of VFD cables, including Belden 29506 and other top-rated options designed for Variable Frequency Drive applications. Our VFD cables feature shielded motor cables, VFD power cables, and flexible drive cables, ensuring excellent performance and durability. With insulation materials like XLPE and conductor options such as bare or tinned copper, our VFD rated cables provide superior electrical performance and temperature resistance. Browse OmniCable’s inventory to find the perfect VFD cable by AWG size, cable type, conductor count, and voltage rating. Choose OmniCable for reliable, high-performance VFD cables today!
Belden 29506F 0103000 VFD 100% Gnd, 3C #4 Str TC XLPO Ins + #4 Symm. Seg. Gnd (3 of #8) Str BC, OS+TC Brd, Blk TPE Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V WTTC
- Conductor Material: Tinned Copper
- Product Category: High Flex VFD
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Foil + Braid(s)
- Stranding Material: Tinned Copper - Stranded
Belden 29729C 0103000 VFD, 3C #1/0 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Stranding Material: Bare Copper - Stranded
- Insulation Description: XLPE - Cross Linked Polyethylene
- Product Category: Basics VFD - 2000V
- Shielding: Corrugated or Helical Tape(s)
Belden 29732C 0102000 VFD, 3C #4/0 Str BC XLPO Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD - 2000V
Belden 29730C 0102500 VFD, 3C #2/0 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Product Category: Basics VFD - 2000V
- Shielding: Corrugated or Helical Tape(s)
- Insulation Description: XLPE - Cross Linked Polyethylene
- Stranding Material: Bare Copper - Stranded
Belden 29731C 0102500 VFD, 3C #3/0 Str BC XLPO Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD - 2000V
- Insulation Description: XLPE - Cross Linked Polyethylene
Belden 29722C 0105000 VFD, 3C #12 Str BC XLPO Ins + #12 Symm. Seg. Gnd (3 of #16) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Product Category: Basics VFD - 2000V
- Stranding Material: Bare Copper - Stranded
Belden 29721C 0105000 VFD, 3C #14 Str BC XLPO Ins + #14 Symm. Seg. Gnd (3 of #18) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Insulation Description: XLPE - Cross Linked Polyethylene
- Stranding Material: Bare Copper - Stranded
- Shielding: Corrugated or Helical Tape(s)
- Product Category: Basics VFD - 2000V
Belden 29727C 0105000 VFD, 3C #2 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Shielding: Corrugated or Helical Tape(s)
- Product Category: Basics VFD - 2000V
- Insulation Description: XLPE - Cross Linked Polyethylene
- Stranding Material: Bare Copper - Stranded
Belden 29728C 0105000 VFD, 3C #1 Str BC XLPO Ins + #5 Symm. Seg. Gnd (3 of #10) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Product Category: Basics VFD - 2000V
- Insulation Description: XLPE - Cross-Linked Polyethylene (Thermoset)
- Stranding Material: Bare Copper - Stranded
- Shielding: Corrugated or Helical Tape(s)
Belden 29724C 0105000 VFD, 3C #8 Str BC XLPO Ins + #10 Symm. Seg. Gnd (3 of #14) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Product Category: Basics VFD - 2000V
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded
Belden 29723C 0105000 VFD, 3C #10 Str BC XLPO Ins + #10 Symm. Seg. Gnd (3 of #14) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Shielding: Corrugated or Helical Tape(s)
- Insulation Description: XLPE - Cross Linked Polyethylene
- Stranding Material: Bare Copper - Stranded
- Product Category: Basics VFD - 2000V
Belden 29725C 0105000 VFD, 3C #6 Str BC XLPO Ins + #6 Symm. Seg. Gnd (3 of #12) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B
- Conductor Material: Bare Copper
- Product Category: Basics VFD - 2000V
- Insulation Description: XLPE - Cross Linked Polyethylene
- Shielding: Corrugated or Helical Tape(s)
- Stranding Material: Bare Copper - Stranded